  • Ideal for manual dead testing

  • Can be easily operated and adapted to perform an array of basic tests

  • Display turns red or green to indicate PASS/FAIL

-+
£595.00
Save £296.00
£299.00
£358.80 (Inc. VAT)

Login / Sign Up
Why do I need a calibration?

Found it Cheaper? Found it Cheaper? Price Match
Need Help? Need Help? Contact Us

Kewtech EZYPAT PAT Tester

Click to enlarge

Select a Free PAT Bundle

  • PAT Handbook, Logbook, Cloverleaf & 500 Pass / 250 Fail Labels
    FREE   £55.45
  • Description

Kewtech EZYPAT PAT Tester – Battery Operated Details

The Kewtech EZYPAT PAT Tester can be used to manually conduct dead testing on extension leads, Class I and Class II appliances that do not require a power supply to start up, i.e. items WITHOUT electronic on/off switches.

PLEASE NOTE that the EZYPAT PLUS, available here, is suited to testing items (such as computers and TVs) with electronic on/off switches and which do require a power supply to start up. For more information regarding Kewtech's EZYPAT/SMARTPAT range, please see the comparison table detailed in the 'Technical Specifications'.

Nevertheless, the Kewtech EZYPAT PAT Tester is IT safe as it features a low current, 200mA earth continuity test and 250V DC insulation test.

Moreover, the Kewtech EZYPAT PAT Tester’s accompanying EZYLEAD Extension Lead Adapter and EZYEARTH Earth Continuity Test Lead with Probe and Crocodile Clip, as well as its Test Lead Null function all allow the user to quickly adapt this product to perform a variety of tests accurately.

Adding to this product’s adaptability is its choice of voltages for insulation tests (250V DC or 500V DC) and selectable substitute leakage test limits.

There are a number of tests available on the Kewtech EZYPAT PAT Tester, including:

  • Appliance status pre-check (determines whether the appliance under investigation is on or off)
  • Quick check continuity (1 second)
  • 5-second continuity check
  • Insulation tests (using either 250V DC or 500V DC)
  • Substitute leakage test
  • Extension lead test
  • 200mA earth test

The results of these tests are clearly displayed on the Kewtech EZYPAT PAT Tester’s large, backlit display. This display will turn red if an appliance has failed a test and green when an appliance has passed. This display feature adds to the Kewtech EZYPAT’s efficiency and ease-of-use; other features which make using the Kewtech EZYPAT PAT Tester quick and convenient are its automatic test sequences for Class I and Class II appliances and extension leads, and its lightweight, practical design. All these features allow the user to perform numerous tests quickly in a variety of environments.

Finally, the Kewtech EZYPAT PAT Tester's battery operation also works to make this product convenient and practical, as the user is able to perform approximately 1400 tests before the batteries begin to expire.  This combined with the Kewtech EZYPAT PAT Tester’s numerous other features, accessories and measurement capabilities make it ideal for providing a solution to basic PAT Testing requirements.

Kewtech EZYPAT PAT Tester – Battery Operated Key Features

  • PAT tester optimised for conducting manual dead testing applications on Class I and Class II appliances that do not require a power supply to start up
  • IT safe
  • Low current, 200mA earth continuity test
  • 250V DC insulation test
  • 500V DC insulation test
  • EZYLEAD Extension Lead Adapter
  • EZYEARTH Earth Continuity Test Lead with Probe and Crocodile Clip
  • Test Lead Null function
  • Selectable substitute leakage test limits
  • Appliance status pre-check (determines whether the appliance under investigation is on or off)
  • Quick check continuity (1 second)
  • 5-second continuity check
  • Insulation tests (using either 250 or 500V DC)
  • Substitute leakage test
  • Extension lead test
  • Large, backlit display
  • Display turns red for FAIL
  • Display turns green for PASS
  • Automatic test sequences for Class I and Class II appliances and extension leads
  • Lightweight, practical design
  • Perform up to approximately 1400 tests before batteries expire

What’s Included?

  • Kewtech EZYPAT PAT Tester – Battery Operated
  • EZYLEAD Extension Lead Adapter
  • EZYEARTH Earth Continuity Test Lead with Probe and Crocodile Clip
  • Carry Bag with Strap
  • Quick Start Guide

 

Questions?Do you have a question about this product? Call our customer service team on 01642 631685.
  • Technical Specs

Kewtech EZYPAT/ SMARTPAT Comparision Table

Specification EZYPAT EZYPAT PLUS SMARTPAT
200mA Continuity Test  X X X
250V Insulation Test X X X
500V Insulation Test X X X
Substitute Leakage Test X X X
Polarity Check X X X
110V Load and Run Test X X
230V Load and Run Test X X
Portable RCD Test X
Compatible with KEWPAT App X
Customisable Test Sequences X

Kewtech EZYPAT PAT Tester – Battery Operated Technical Specifications

Protective Conductor Resistance Test
Measuring Range 0.00 - 20.00 Ω (NULL value inc)*
Over-range Indication > 20.00 Ω
Resolution 0.01Ω
Open-circuit Voltage 5 V ±0.4 V DC
Measuring Current 200 mA DC (nominal value)
Accuracy ±3%rdg ±5dgt

* Resistances exceeding 3 Ω cannot be cancelled by NULL function.

Insulation
Measuring Range  0.00 - 20.00 MΩ
Over-range Indication > 20.00 MΩ
Resolution 0.01 MΩ
No-load Voltage 250V : 250 V DC +20%, -0%
500V: 500 V DC +20%, -0%
Short-circuit Current 1.5 mA DC or less
Rated Current 250V: 1 -1.2 mA with a load of 0.25 MΩ
500V: 1 to 1.2 mA with a load of 0.5 MΩ
Accuracy ±2%rdg±3dgt
Substitute Leakage 
Measuring Range 0.10 - 12.00 mA rms
Over-range Indication > 12.00 mA
Resolution 0.01mA
Open-circuit Voltage/ Frequency 30 V ±5 V rms / 50 Hz ±5%
Measuring Circuit 1.2 mA AC ±0.5 mA (when measuring 12.00 mA)
Accuracy ±3%rdg±5dgt
Insulation Testy Between L-N
Open-circuit Voltage 4.5 V ±0.5 V DC
Criteria of Judgement

100 kΩ ±20 kΩ or less: LCD shows “<0.10 MΩ” and the measurement is halted.

Physical Specifications
Safety 

IEC/EN61010-1 CAT II 300V-instrument
IEC/EN61010-2-030
IEC/EN61010-031 CAT III 600V

EMC EN61326-1, 2-2

Possible number of
measurements where
battery voltage is within the
effective range (measuring
every 30 sec)

Approx. 1400 times
(CLI Rpe: 0 Ω, Rins: 1.1 MΩ)

Boxed Weight  1.61Kg
Boxed Dimensions (L x W x D) 261 x 140 x 130mm
Questions?Do you have a question about this product? Call our customer service team on 01642 631685.
  • Reviews

We'd really appreciate it if you'd review this product

No reviews have been found

Write Your Own Review

You're reviewing: Kewtech EZYPAT PAT Tester – Battery Operated

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Price
Value
Quality

1.9