All Megger Products

Megger PAT120 PAT Tester

SKU
1003-062
Rating:
0%
(0)
Reward Points
:
409
£490.80 £409.00
3 in Stock
Free UK Delivery*
Choose a Special Offer
  • Essential Bundle (1,000 Labels & Logbook)
    Essential Bundle (1,000 Labels & Logbook)
    FREE
    £77.98
  • Essential Bundle (1,000 Labels & Logbook) SKU: (PAT-ESSENTIAL-BUNDLE)
    FREE
    £77.98
    Essential Bundle (1,000 Labels & Logbook)
  • IT Bundle (3 x IEC Adaptors & Socket Tester) - red casing
    IT Bundle (3 x IEC Adaptors & Socket Tester)
    FREE
    £46.96
  • IT Bundle (3 x IEC Adaptors & Socket Tester) SKU: (PAT-IT-BUNDLE)
    FREE
    £46.96
    IT Bundle (3 x IEC Adaptors & Socket Tester) - red casing
  • Tolsen Tools 7-Piece Insulated Screwdriver Set
    Tolsen Tools 7-Piece Insulated Screwdriver Set
    FREE
    £16.99
  • Tolsen Tools 7-Piece Insulated Screwdriver Set SKU: (TS-9900012)
    FREE
    £16.99
    Tolsen Tools 7-Piece Insulated Screwdriver Set
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
FREE PAT Accessory Bundle
Megger PAT120 PAT Tester

Compact, rugged and with everything you need to test electrical appliances - Megger's PAT120 is an excellent PAT testing solution for any low volume PAT user such as shops, offices and anywhere else without a large amount of appliances to test.

Both a PASS/FAIL PAT checker and a full PAT tester, the PAT120 shows a tick/cross to indicate if an appliance has passed or failed a test and also shows a full testing reading simultaneously on the built-in backlit scratch-proof LCD screen. Test procedures can be easily accessed and activated using dedicated testing buttons underneath the screen and a built-in plug port makes connection easy.

Designed for easy transportation, the PAT120 is powered by standard AA batteries and can be used wherever you need it. The tester is fully suitable for use on class I and class II appliances, leads, extension leads and includes 250/500V insulation testing procedures that make the tester suitable for use on IT-based and surge-protected electrical equipment.

Worried about the tester getting damaged? With the PAT120 - you don't have to! It comes built into its own protective, heavy-duty carrying case with flip-down lid for protecting the screen and internal keys.

Megger PAT120 PAT Tester Key Features

  • Extremely simple to use - shows a tick/cross to indicate PASS/FAIL and also shows full testing readings
  • Tough, rubber-armoured casing with flip-down protective cover
  • 250V/500V insulation testing + leakage testing for IT/surge-protected devices
  • Portable design - powered by batteries for easy transportation from test to test
  • Dedicated testing buttons give quick and easy access to all functions
  • Suitable for use with Class I and Class II appliances, associated leads and extension leads
  • Runs on standard AA batteries
  • Backlit LCD screen with special tough scratch-resistant coating

What's Included?

  • Megger PAT120 PAT Tester
  • 4mm Plug Lead Probe + Crocodile Clip
  • Extension Lead Adaptor
  • Carrying Case

PAT120 or PAT150?

Megger have also developed a full-featured version of the PAT120 known as the PAT150. This product is ideally suited for those looking for more testing procedures and more advanced features. The chart below outlines the difference between the PAT120 and the PAT150.

FeatureMegger PAT120Megger PAT150
Mains Test Socket BS1363 BS1363
Power Supply AA alkaline batteries AA alkaline batteries
Testing    
Protective Earth Resistance
250V Insulation
500V Insulation -
Cable Test
Live Protective Conductor Current -
Live Touch Current -
Substitute Leakage
Function Test (Part of Live Leakage Test) -
10mA PRCD -
30mA PRCD -
SELV Voltage -
Lead Resistance Nulling -
Function Keys    
Class 1
Class 2
Lead/Cord
PRCD -
Single Test -
LCD Backlight
Setup -
On/Off
Standard Accessories    
4mm Plug Lead Probe + Croc Clip 1x 2x
Extension Lead Adaptor BS1363 BS1363
Mains Supply Cord -
Carry Case

Don't Forget Your Calibration Certificate!

At PATTesters.co.uk we are able to calibrate your new tester from the day of purchase, ensuring you get the longest life out of your new product. To use our calibration service just add an optional calibration certificate to your order using the selection at the top of the page.

Get More with Our Megger PAT120 PAT Kits!

If you're looking for a comprehensive PAT kit - we've got you covered.

We have two different, great value kit versions of the Megger PAT120 available - take a look at the table below for a closer look about what's in each.

Item Description  Megger PAT120 PAT Essentials Kit (Bundle 1)Megger PAT120 PAT Tester Professional Kit (Bundle 2)

Deluxe Carrying Case

Keep all of your equipment safe and in one place with this large-size carrying case!

(appearance of case may vary depending on current stock)

Socket Tester

Need to check if your sockets are working right? Just plug this in to a standard UK plug socket and if there's a problem, the socket tester will let you know about it!

(socket tester may vary depending on current stock)

PAT Testing Training DVD +
Online Exam & Certificate for 1 Person

Not yet trained as a PAT tester? With our training DVD, you can train yourself from the comfort of your own home or workplace! The DVD includes access to our online examination for one person (you can also purchase additional exams for other team members, if needed).

The PASS Handbook of Portable Appliance Testing

Everything you need to know about PAT testing is outlined in this comprehensive book. Inside, you'll find useful information, colour-coded sections, photographic examples and much more to help you PAT test on a daily basis.

PASS PAT Testing Logbook

Keep a record of all of your testing with our logbook. The book includes carbon-copied records, allowing you to keep one for yourself and give the other to customers or keep for a reference.

Microwave Leakage Detector

When PAT testing, it's common practice to check microwaves are also not emitting high levels of radiation. With our microwave leakage detector you'll be able to do this testing with ease.

PASSPTA21 - IEC (C13 Female)
to Cloverleaf (C6 Male) PAT Adaptor

You'll need this adaptor to connect your PAT tester to laptop/PC power leads and other similar equipment which has a cloverleaf-shaped connector.

PASSPTA29 - IEC Plug (C14)
to Cloverleaf (C5) PAT Adaptor

This adaptor is used to connect to laptop power supplies, portable projectors and other similar equipment.

PASSPTA28 - IEC Plug (C14)
to Fig 8 (C7) Pat Adaptor

You'll find several appliances such as game consoles, laptop power supplies, audio/visual equipment and more use this type of connector - with this adaptor, you can connect them up to your PAT tester.

CK Tools AV05050 5 Piece Insulated Screwdriver Kit

A handy set of insulated screwdrivers (suitable for live working to 1000V) suitable for a wide variety of applications.
Includes 2 x PZ (1 x 80 and 2 x 100mm) + 3 x slotted (3 x 75, 4 x 100 and 5.5 x 125mm) screwdrivers in a carrying case.

WM1 - 500 x Passed PAT Testing Labels

You'll need these every time an appliance passes a test - just tear one off, fill in the fields (appliance ID, your name, test date and next test due date) and stick on the appliance when done.

WM6500 - 500 x Circular Passed PAT Testing Labels

These circular-shaped PAT labels are great for plug tops and any other appliance. The labels also include space for ticking the month/year the next test is due.

WM12 250 - 250 x Cable Wrap Labels

These passed labels wrap around a wire/cable from an appliance and are recommended for use with power supplies or on appliances where you can't stick a label. They also include space for writing your appliance ID, name, test date and next test date.

WM7 250 - 250 x Failed PAT Testing Labels

You won't need these as often as your passed labels, but you'll need to apply one of these whenever an appliance fails a test. If it does fail, the item should be taken out of service for repair or replacement

SimplyPats Manual PAT Testing Software

Keep a database of your PAT testing information on your PC and print reports with SimplyPats Manual software. Please note that this software is manual entry; you cannot download directly from the PAT tester and you will need to type in records by hand.

-

Accessories

The table below details the accessories available for the Megger PAT120 Manual PAT Tester. For further information, please contact our sales team. 

Our SKU Megger's Part Number Product 
2000-870 1001-233 Continuity/Bond Lead Set 32A 
1001-234 1001-234 Extension Lead Adaptor 230V UK 13A
1003-346 1003-346 Battery Charger Kit 15V
1005-075 1005-075 Carry Case PAT100 Series  
1005-076 1005-076 Carry Strap
1005-077 1005-077 SELV Test Lead 
1005-081 1005-081 Extension Lead Adaptor SWISS 
MEGRCDA1 6231-601 UK Mains Plug Test Leadset 3-pin 1 wire (BS1363 plug)
2000-551 1001-232 Megger Plug adaptor IEC C6 - C13
MEGPTA8 6220-639 Megger 6220-639 Extension Lead Adapter (ELA) 110V  BS4343 (for PAT4DV & DVF)
1000-767 1000-767 415V Adaptor Lead (4 Pin) TO BS (16A)
1000-770 1000-770 415V Adaptor Lead (5 Pin) TO BS (16A)

Megger PAT100 Series Technical Specifications

SpecificationsMegger PAT120Megger PAT150
Environmental Conditions    
Operating Ambient 20°C 20°C
Humidity Nominal humidity Nominal humidity
Continuity Testing    
Test Voltage Compliance voltage: +4V DC
-0 / +10% (open circuit)
Compliance voltage: +4V DC
-0 / +10% (open circuit)
Test Current Bi-directional +200mA
-0% + 50mA (into 2Ω load)
Bi-directional +200mA
-0% + 50mA (into 2Ω load)
Continuity Accuracy Resistance: ±5% ± 3 digits (0 to 19.99Ω) Resistance: ±5% ± 3 digits (0 to 19.99Ω)
Resistance Resolution 10mΩ 10mΩ
Display Range 0.01 to 19.99Ω 0.01 to 19.99Ω
Continuity Test Nulling Up to 9.99Ω Up to 9.99Ω
Test Duration Selected during test automatically User-selectable from 2 seconds to 20 seconds or selected during test to 180 seconds
Insulation Test    
Insulation Procedure 250V DC: -0% / +25% open circuit 250V DC: -0% / +25% open circuit
500V DC: -0% / +25% open circuit
≥ 500V 0% DC across 0.5MΩ load
Short Circuit/Charge Current <2mA DC <2mA DC
Insulation Accuracy ±3% ± 10 digits (0 to 99.9MΩ) ±3% ± 10 digits (0 to 99.9MΩ)
Resolution 0.01MΩ 0.01MΩ
Display Range 0.10M to 99.99MΩ 0.10M to 99.99MΩ
Test Duration Selected during test automatically User selectable from 2 seconds to 20 seconds or selected during test to 180 seconds
Substitute Leakage Test    
Leakage Current Accuracy ±5% ± 3 digits Accuracy ±5% ± 3 digits
Test Frequency Nominal mains frequency 50Hz Nominal mains frequency 50Hz
Test Voltage <50V AC <50V AC
Resolution 0.01mA 0.01mA
Display Range 0.10 to 19.99mA 0.10 to 19.99mA
Test Duration User-selectable from 2 secs to 5 seconds User-selectable from 2 secs to 5 seconds
Differential Leakage Test (PAT150 Only)    
Test Voltage - Nominal supply voltage 230V AC
Test Frequency - Nominal mains frequency 50Hz
Test Accuracy - ±5% ±3d ± 3μA/A
Resolution - 0.01mA
Display Range - 0.10 to 19.99mA
Test Duration - User-selectable from 2 seconds to 5 seconds
Touch Current Test (PAT150 Only)    
Test Voltage - Nominal mains 230V AC
Test Frequency - Nominal mains 50Hz
Test Accuracy - ±5% ± 3 digits
Resolution - 0.01mA
Display Range - 0.10 to 3.99mA
Test Duration - User-selectable from 2 seconds to 5 seconds
SELV Device Test (PAT150 Only)    
Test Voltage - 0 to 300V AC
Measurement Accuracy - ±3% ± 3 digits
Resolution - 0.1V AC
Display Range - 0.1 to 300V AC
Extension Lead Test    
Test Voltage 5V 5V
Polarity Lead OK
Live/neutral shorted
Live/neutral reversed
Live/neutral open circuit
Lead OK
Live/neutral shorted
Live/neutral reversed
Live/neutral open circuit
Portable RCD Test (PAT150 Only)    
Test Voltage - Nominal mains 230V
Test Frequency - 50Hz
Test Current Accuracy - +2% to +8% (1 x I, 5 x I)
Trip Time Accuracy - ±1% ± 1ms
Trip Time Resolution - 0.01ms
Display Range - 0 to 200ms (1 x I)
0 to 40ms (5 x I)
Mains Supply Test (PAT150 Only)    
Frequency Measurement Range - 50Hz
Test Voltage - 40 to 300V AC
Accuracy - ±3% ± 3 digits
Resolution - 0.1V AC
Display Range - 40 to 300V AC
Circuit Test    
Test Voltage 5V 5V
Test Frequency Nominal mains 50Hz Nominal mains 50Hz
Test Current <100mA short circuit <100mA short circuit
Safety Instrument designed to IEC 61010-1: 2012
Test leads designed to IEC 61010-031:2005
300 volts to Earth Category II
Mains fuse protection to 250V RMS AC
Instrument designed to IEC 61010-1: 2012
Test leads designed to IEC 61010-031:2005
300 volts to Earth Category II
Mains fuse protection to 250V RMS AC
EMC Designed to meet IEC 61326-1: 2006 and IEC 61326-2-2: 2005 Designed to meet IEC 61326-1: 2006 and IEC 61326-2-2: 2005
Environmental    
Operating Temperature 0 to 40°C 0 to 40°C
Storage Temperature -20 to 60°C -20 to 60°C
Humidity 90% RH @ 10 to 30°C
75% RH @ 30 to 40°C
90% RH @ 10 to 30°C
75% RH @ 30 to 40°C
Max Altitude 2000m to full safety spec 2000m to full safety spec
IP Rating IP40 (with front cover closed) IP40 (with front cover closed)
Mechanical (Batteries)    
Battery Life 3 days based on 120 tests/day using 2000mAh alkaline batteries 3 days based on 120 tests/day using 2000mAh alkaline batteries
Battery Type Supply voltage
12V DC (alkaline AA LR6)
9.6V DC (NiMH AA LR6)
Supply voltage
12V DC (alkaline AA LR6)
9.6V DC (NiMH AA LR6)
Weight 1150g 1300g
Dimensions 203mm (L) x 148mm (W) x 78mm (H) 203mm (L) x 148mm (W) x 78mm (H)
Accessories related to this product:
Megger PAT120, PAT150, PAT150R PAT Tester - Datasheet Datasheets

Reviews

Additional Information
SKU 1003-062
Manufacturer Part Code 1003-062
Model No PAT120
Country of Origin United Kingdom