Transmille 6080 Plus PAT Tester

RRP £899.00

You Save £174.00

£725.00+VAT  qty

£851.88 inc VAT

Add Calibration £25.00+VAT

Order Code: TRAPT3

Features

Battery Powered
Battery Powered
These PAT Testers offer great flexibility as there is no need to plug them into a mains socket.
Extension Lead Test
Extension Lead Test
PAT Testers with an inbuilt lead length calculator for long cables and extension leads will save a lot of headaches.
Downloadable
Downloadable
Generally, PAT Testers with a memory can be downloaded to reporting software. This can then be made into reports.
Earth Bond Test

100mA
25A 10A

Earth Bond Test
The Earth Bond Test (Earth Continuity Test) is carried out on all earthed appliances. An Earth Bond Test shows whether the earth conductor is in a satisfactory condition.
Tests IT Equipment
Tests IT Equipment
This PAT Tester is suitable for testing IT and electronic equipment with a low current Earth Bond Test (usually either 100mA or 200mA).
Tester Has Memory

600

Tester Has Memory
This allows the tester to store an allocated number of tests. These results can then be downloaded into reporting software.
110v Run Test
110v Run Test
Most industrial and construction equipment is powered by 110v. A 110v Run Test (also known as Load Test) is required for this.
Connects To Scanner
Connects To Scanner
A scanner can speed up your PAT Testing a great deal. If you require a scanner, then you must choose a PAT Tester with scanner compatibility.
Insulation Test

500V

Insulation Test
The Insulation Test measures the insulation resistance of a device under test. A 250v Insulation Test overcomes problems in testing surge protected extension leads.
Weight

3.9Kg

Weight
If you need to walk between tests make sure you pick a PAT Tester with a comfortable weight.

Description

The Transmille 6080 Plus has all of the functions of a good PAT Tester with dual voltage capability for complete 110V/230V compatibility with sockets for each voltage. The IEC / extension lead check function allows leads to be verified at the press of a button. Using the self check function, the Transmille 6080 Plus PAT Tester can be verified using its own built in test facility – simply connect to the self check terminals to verify PAT operation. This unique function avoids the need for a separate test box. The Transmille 6080 Plus PAT Tester also includes larger battery capacity to provide typically up to 700 tests between charging.

Transmille 6080 Plus key features

  • 600 result memory storage
  • Flash test
  • Battery operation
  • No mains connection required
  • 230V output
  • Visual check : Fuse (load) test
  • Insulation resistance at 500V
  • Leakage current
  • Earth bond (25/10/100mA)
  • 110V at 230V output
  • IEC/extension lead test
  • Fuse check
  • Self check
  • Extended battery life

Transmille 6080 Plus suitability

  • PAT testers
  • Electrical contractors
  • Manufacturers
  • Facilities managers
  • Schools and colleges

Transmille 6080 Plus comes supplied with

  • Transmille 6080 Plus PAT Tester
  • Transmille 6080 Plus instruction manual
  • Removable earth bond lead
  • Power charger
  • 12 months manufacturers warranty
PATFINDER

Too many to choose from? Use the quick quide:

Show me....

Open
All PAT Testers
Basic PAT Testers
Mid-Range PAT Testers
Professional PAT Testers
What features would you like your PAT tester to have?

 

Battery Powered
Battery Powered
These PAT Testers offer great flexibility as there is no need to plug them into a mains socket.
Manual
Manual
PAT Testers without memory require you to record results in a PAT Log Book. Results can be manually typed into software to create reports.
Extension Lead Test
Extension Lead Test
PAT Testers with an inbuilt lead length calculator for long cables and extension leads will save a lot of headaches.
Downloadable
Downloadable
Generally, PAT Testers with a memory can be downloaded to reporting software. This can then be made into reports.
Earth Bond Test
Earth Bond Test
The Earth Bond Test (Earth Continuity Test) is carried out on all earthed appliances. An Earth Bond Test shows whether the earth conductor is in a satisfactory condition.
Flash Test
Flash Test
Flash Testing is a high tension insulation test which is no longer a requirement in normal PAT Testing. The only time it is required is after the replacement of a major component in an appliance, such as a motor.
Tests IT Equipment
Tests IT Equipment
This PAT Tester is suitable for testing IT and electronic equipment with a low current Earth Bond Test (usually either 100mA or 200mA).
Tester Has Memory
Tester Has Memory
This allows the tester to store an allocated number of tests. These results can then be downloaded into reporting software.
Mains Powered
Mains Powered
These PAT Testers offer a wider range of tests and are powered by a mains socket.
Connects To Printer
Connects To Printer
A Printer can speed up your PAT Testing a great deal. If you require a printer, then you must choose a PAT Tester with printer compatibility.
110v Run Test
110v Run Test
Most industrial and construction equipment is powered by 110v. A 110v Run Test (also known as Load Test) is required for this.
Connects To Scanner
Connects To Scanner
A scanner can speed up your PAT Testing a great deal. If you require a scanner, then you must choose a PAT Tester with scanner compatibility.
Insulation Test
Insulation Test
The Insulation Test measures the insulation resistance of a device under test. A 250v Insulation Test overcomes problems in testing surge protected extension leads.
Calibration Included
Calibration Included
A manufacturer calibration certificate is included with these PAT Testers. This certificate starts from the date of manufacture, so it is recommended that you still add a new calibration certificate.

Features

CATALOGUE

Request a PAT Catalogue full of testers and accessories completely FREE!

PATBRANDS

View all PAT equipment and Accessories by brand

Click the brand you want to see below:

TOPTENS

Want to know what's popular? View our Top Tens.