6080 Plus PAT Tester

Transmille 6080 Plus PAT Tester

Click image above to enlarge.

RRP £899.00

You Save £174.00

£725.00+VAT x  qty

£851.88 inc VAT

Add Calibration £25.00+VAT

Order Code: TRAPT3

Features

Technical Info

Click tab for Datasheets & Manuals

battery
Battery Powered
These PAT Testers offer great flexibility as there is no need to plug them into a mains socket.
extension
Extension Lead Test
PAT Testers with an inbuilt lead length calculator for long cables and extension leads will save a lot of headaches.
downloadable
Downloadable
Generally, PAT Testers with a memory can be downloaded to reporting software. This can then be made into reports.
earthbond

100mA
25A 10A

Earth Bond Test
The Earth Bond Test (Earth Continuity Test) is carried out on all earthed appliances. An Earth Bond Test shows whether the earth conductor is in a satisfactory condition.
it
Tests IT Equipment
This PAT Tester is suitable for testing IT and electronic equipment with a low current Earth Bond Test (usually either 100mA or 200mA).
memory

600

Tester Has Memory
This allows the tester to store an allocated number of tests. Results can be downloaded into reporting software but can only be viewed on screen if it is a manual PAT tester.
runtest
110v Run Test
Most industrial and construction equipment is powered by 110v. A 110v Run Test (also known as Load Test) is required for this.
scanner
Connects To Scanner
A scanner can speed up your PAT Testing a great deal. If you require a scanner, then you must choose a PAT Tester with scanner compatibility.
insulation

500V

Insulation Test
The Insulation Test measures the insulation resistance of a device under test. A 250v Insulation Test overcomes problems in testing surge protected extension leads.
weight

3.9Kg

Weight
If you need to walk between tests make sure you pick a PAT Tester with a comfortable weight.

Download technical PDFs for further information on this product.

Get Adobe Acrobat Reader

Description

The Transmille 6080 Plus PAT Tester is one of our mid to professional range PAT Testers and comes completed with a dual voltage capability of 110v/230v to test all voltages of sockets.

With this PAT Tester you can, at the press of a button, test extension leads/IEC leads with the quick check function. You can check and verify the 6080 PAT Tester by using it’s built in self check function – you connect it to its own self check terminals to verify PAT operation. Due to this quirky function you don’t need a separate checkbox.

The difference between the 6080 Plus and the 6080 from Transmille is the PLUS has a QWERTY keyboard and a smaller result memory storage capacity as a result compared to the normal Transmille 6080 PAT Tester.

Because the Transmille Plus 6080 PAT Tester has larger battery ability it can do up to 700 tests between charges.

 

Key features of the Transmille 6080 Plus PAT Tester

  • 600 result memory storage
  • Qwerty Keyboard
  • Flash test
  • Battery operation
  • Insulation resistance at 500V
  • Leakage current
  • Earth bond (25/10/100mA)
  • 110V at 230V output
  • IEC/extension lead test
  • Fuse check
  • Self check
  • No mains connection required
  • 230V output
  • Visual check : Fuse (load) test
  • Extended battery life

 

Transmille 6080 Plus PAT Tester suitability

  • PAT testers
  • Facilities managers
  • Schools, colleges and universities
  • Electrical contractors

 

Transmille 6080 Plus PAT Tester comes supplied with

  • Transmille 6080 Plus PAT Tester
  • Transmille 6080 Plus instruction manual
  • Removable earth bond lead
  • Power charger
  • 12 months manufacturer’s warranty

Further information:

  • Calibration certificate not included
  • Free delivery included

Help Centre

At PAT Testers we have a comprehensive Help Centre with dozens of answer FAQs and supporting videos. Some related FAQs are below and if you still need some help, why not seach our PAT Tester Help Centre.

PATFINDER

Too many PAT testers to choose from?
Using the quick guide can help:

Show me....

Open
All PAT Testers
Basic
Mid-Range
Professional
What features would you like your PAT tester to have?

 

battery
Battery Powered
These PAT Testers offer great flexibility as there is no need to plug them into a mains socket.
manual
Manual
PAT Testers without memory require you to record results in a PAT Log Book. Results can be manually typed into software to create reports.
extension
Extension Lead Test
PAT Testers with an inbuilt lead length calculator for long cables and extension leads will save a lot of headaches.
downloadable
Downloadable
Generally, PAT Testers with a memory can be downloaded to reporting software. This can then be made into reports.
earthbond
Earth Bond Test
The Earth Bond Test (Earth Continuity Test) is carried out on all earthed appliances. An Earth Bond Test shows whether the earth conductor is in a satisfactory condition.
flashtest
Flash Test
Flash Testing is a high tension insulation test which is no longer a requirement in normal PAT Testing. The only time it is required is after the replacement of a major component in an appliance, such as a motor.
it
Tests IT Equipment
This PAT Tester is suitable for testing IT and electronic equipment with a low current Earth Bond Test (usually either 100mA or 200mA).
memory
Tester Has Memory
This allows the tester to store an allocated number of tests. Results can be downloaded into reporting software but can only be viewed on screen if it is a manual PAT tester.
mains
Mains Powered
These PAT Testers offer a wider range of tests and are powered by a mains socket.
printer
Connects To Printer
A Printer can speed up your PAT Testing a great deal. If you require a printer, then you must choose a PAT Tester with printer compatibility.
runtest
110v Run Test
Most industrial and construction equipment is powered by 110v. A 110v Run Test (also known as Load Test) is required for this.
scanner
Connects To Scanner
A scanner can speed up your PAT Testing a great deal. If you require a scanner, then you must choose a PAT Tester with scanner compatibility.
insulation
Insulation Test
The Insulation Test measures the insulation resistance of a device under test. A 250v Insulation Test overcomes problems in testing surge protected extension leads.
rcd
RCD Test
Many newer PAT testers incorporate this test because it is a requirement of the IEE Code of Practice 3rd Edition.
calibration
Calibration Included
A manufacturer calibration certificate is included with these PAT Testers. This certificate starts from the date of manufacture, so it is recommended that you still add a new calibration certificate.

Features

request a free catalogue
PATBRANDS

View all PAT equipment and Accessories by brand

Click the brand you want to see below: