>
KT71 PAT Tester Kit 3 With Microwave Leakage Detector

Kewtech KT71 PAT Tester Kit 3 with Microwave Leakage Detector

Kewtech KT71 Kit 3 Box
Click image above and thumbnails to enlarge.

RRP £580.75

You Save £75.75

£505.00+VAT x  qty

£593.38 inc VAT

Add Calibration £25.00+VAT

Order Code: KT713

Features

Technical Info

Click tab for Datasheets & Manuals

manual
Manual
PAT Testers without memory require you to record results in a PAT Log Book. Results can be manually typed into software to create reports.
extension
Extension Lead Test
PAT Testers with an inbuilt lead length calculator for long cables and extension leads will save a lot of headaches.
earthbond

200mA
20A

Earth Bond Test
The Earth Bond Test (Earth Continuity Test) is carried out on all earthed appliances. An Earth Bond Test shows whether the earth conductor is in a satisfactory condition.
it
Tests IT Equipment
This PAT Tester is suitable for testing IT and electronic equipment with a low current Earth Bond Test (usually either 100mA or 200mA).
mains
Mains Powered
These PAT Testers offer a wider range of tests and are powered by a mains socket.
insulation

250
500V

Insulation Test
The Insulation Test measures the insulation resistance of a device under test. A 250v Insulation Test overcomes problems in testing surge protected extension leads.
weight

1.2Kg

Weight
If you need to walk between tests make sure you pick a PAT Tester with a comfortable weight.
calibration
Calibration Included
A manufacturer calibration certificate is included with these PAT Testers. This certificate starts from the date of manufacture, so it is recommended that you still add a new calibration certificate.

Download technical PDFs for further information on this product.

Get Adobe Acrobat Reader

Description

Kewtech KT71 PAT Tester Kit 3 comes supplied with

  • Microwave Leakage Detector
  • SimplyPATS Manual Software
  • The Essential Guide to PAT Testing Training DVD - PAT testing course on DVD with free online exam and qualification
  • 500 Passed Labels
  • 500 Failed Labels
  • 500 Cable Wraps
  • 240v Plug to 10amp IEC Lead for testing 240v Extension Cables
  • 110v Socket to 10amp IEC Lead for testing 110v Extension Cables
  • PAT Testing Log book (to record your test results)
  • Deluxe Carry Case for easy transportation and protection of your PAT Testing Kit!  Comes with customisable foam, so you can snugly fit whatever equipment you would like to take on site
  • FREE DELIVERY

 

Kewtech KT71 comes supplied with

  • Kewtech KT71 PAT Tester
  • Kewtech KT71 user manual
  • Earth bond test lead
  • Mains lead and car charger
  • 2 year warranty


This PAT Tester comes with a Calibration Certificate
 

Kewtech KT71 description

The Kewtech KT71 PAT Tester is a popular mains powered PAT Pester. It is Easy to use and great for low volume testing!

The Kewtech KT71 is great for in-house maintenance staff who conduct their own yearly PAT Testing. It is also suitable for electrical contractors who need to have a PAT Testing capability, but for whom it is not core for their business. Anyone can easily be trained to use this instrument with complete safety.

LED indicators give visual pass/fail indication with limits set in accordance with the IET (IEE) Code of Practice. This means that, in most cases, users will not have to interpret the results. However if you wish the Kewtech KT71 PAT Tester gives you the readings on the LCD screen.

When switching to live testing (in leakage current mode) audible warnings are given that the appliance is about to come live. A double button press is also required to safeguard against inadvertent switching on of an appliance.
 

PAT Testing with the Kewtech KT71

Class I Test
the Kewtech KT71 automatically goes through the test sequence, for example, it performs the sequence of an earth bond test at 200mA, followed by a check to see whether the user has not forgotten to switch the instrument on, then an insultation test.

The insultation test has a 250V or 500V option and the test sequence also has an option whether a leakage current test is done instead of an insultation test. This corresponds to the IEE Code of Practice which supports a leakage test where insultation tests cannot be safely conducted.

Class I 20A test
Performs the sequence of an earth bond test at 20A, followed by a check to see whether the user has not forgotten to switch the instrument on, then an insulation test.

The Kewtech KT71 insulation test has a 250V or 500V option and the test sequence has an alternative of a leakage current test instead of the insulation test.

This corresponds to the IEE Code of Practice which supports a leakage test where insulation tests cannot be safely conducted or are suspect.

Class II Test
The Class II sequence tests whether the appliance is switched on and then runs an insulation test. A leakage current test (touch current test) can be conducted as an alternative.

Leakage Current (Touch Current) Test
The Leakage Current Test is conducted at mains voltage, a load test and a leakage test is undertaken and the results are shown alternatively on the Kewtech KT71's screen. (Testing at mains voltage gives superior results than instruments that perform this by subsequent leakage tests).
 

Kewtech KT71 key features

  • Easy to use
  • Screen gives PASS/FAIL and test readings
  • Hand held - Portable size
  • Mains powered

 

Kewtech KT71 suitability

  • Maintenance staff
  • Schools and colleges
  • Low volume users
  • Leisure industry
  • Care homes

Help Centre

At PAT Testers we have a comprehensive Help Centre with dozens of answer FAQs and supporting videos. Some related FAQs are below and if you still need some help, why not seach our PAT Tester Help Centre.

PATFINDER

Too many PAT testers to choose from?
Using the quick guide can help:

Show me....

Open
All PAT Testers
Basic
Mid-Range
Professional
What features would you like your PAT tester to have?

 

battery
Battery Powered
These PAT Testers offer great flexibility as there is no need to plug them into a mains socket.
manual
Manual
PAT Testers without memory require you to record results in a PAT Log Book. Results can be manually typed into software to create reports.
extension
Extension Lead Test
PAT Testers with an inbuilt lead length calculator for long cables and extension leads will save a lot of headaches.
downloadable
Downloadable
Generally, PAT Testers with a memory can be downloaded to reporting software. This can then be made into reports.
earthbond
Earth Bond Test
The Earth Bond Test (Earth Continuity Test) is carried out on all earthed appliances. An Earth Bond Test shows whether the earth conductor is in a satisfactory condition.
flashtest
Flash Test
Flash Testing is a high tension insulation test which is no longer a requirement in normal PAT Testing. The only time it is required is after the replacement of a major component in an appliance, such as a motor.
it
Tests IT Equipment
This PAT Tester is suitable for testing IT and electronic equipment with a low current Earth Bond Test (usually either 100mA or 200mA).
memory
Tester Has Memory
This allows the tester to store an allocated number of tests. Results can be downloaded into reporting software but can only be viewed on screen if it is a manual PAT tester.
mains
Mains Powered
These PAT Testers offer a wider range of tests and are powered by a mains socket.
printer
Connects To Printer
A Printer can speed up your PAT Testing a great deal. If you require a printer, then you must choose a PAT Tester with printer compatibility.
runtest
110v Run Test
Most industrial and construction equipment is powered by 110v. A 110v Run Test (also known as Load Test) is required for this.
scanner
Connects To Scanner
A scanner can speed up your PAT Testing a great deal. If you require a scanner, then you must choose a PAT Tester with scanner compatibility.
insulation
Insulation Test
The Insulation Test measures the insulation resistance of a device under test. A 250v Insulation Test overcomes problems in testing surge protected extension leads.
rcd
RCD Test
Many newer PAT testers incorporate this test because it is a requirement of the IEE Code of Practice 3rd Edition.
calibration
Calibration Included
A manufacturer calibration certificate is included with these PAT Testers. This certificate starts from the date of manufacture, so it is recommended that you still add a new calibration certificate.

Features

request a free catalogue
PATBRANDS

View all PAT equipment and Accessories by brand

Click the brand you want to see below: