Seaward PrimeTest 200 PAT Tester

RRP £569.00

You Save £184.00

£385.00+VAT  qty

£452.38 inc VAT

Add Calibration £25.00+VAT

Order Code: SEAPT14

Features

Battery Powered
Battery Powered
These PAT Testers offer great flexibility as there is no need to plug them into a mains socket.
Manual
Manual
PAT Testers without memory require you to record results in a PAT Log Book. Results can be manually typed into software to create reports.
Extension Lead Test
Extension Lead Test
PAT Testers with an inbuilt lead length calculator for long cables and extension leads will save a lot of headaches.
Earth Bond Test

200mA

Earth Bond Test
The Earth Bond Test (Earth Continuity Test) is carried out on all earthed appliances. An Earth Bond Test shows whether the earth conductor is in a satisfactory condition.
Tests IT Equipment
Tests IT Equipment
This PAT Tester is suitable for testing IT and electronic equipment with a low current Earth Bond Test (usually either 100mA or 200mA).
Insulation Test

500V

Insulation Test
The Insulation Test measures the insulation resistance of a device under test. A 250v Insulation Test overcomes problems in testing surge protected extension leads.
Weight

0.8Kg

Weight
If you need to walk between tests make sure you pick a PAT Tester with a comfortable weight.

Description

The Seaward PrimeTest 200 is a 3-IN-1 MULTI-TESTER.

The Seaward PrimeTest 200 battery powered PAT Tester is fast, efficient and convenient. It is ideal for service companies and maintenance staff who have to carry out PAT Testing, installation checking, digital multimeter readings and temperature measurements.

There is nothing worse than carrying a ton of equipment around on site to do a few simple tests.  The Seaward PrimeTest 200 is the answer!  Class I, Class II and IT equipment test are a doddle, as are Installation Tests or DMM readings.

Ten measurement functions make the Seaward PrimeTest 200 a very versatile answer to any professional testers toolbox. Designed to be hand held, the Seaward PrimeTest 200 is easy to use and totally effective.

Battery power makes this PAT Tester light and portable, and with no cables to slow you down, you will be flying from job to job.  Heavy duty casing ensures the Seaward PrimeTest 200 is going to last a very long time.

Seaward PrimeTest 200 key features

  • Battery driven for mains free working
  • Rotary switch test selection
  • Single test button action
  • Tests Class I and Class II equipment
  • Tests Extension and IEC leads
  • Insulation, Continuity, Socket polarity and RCD tests
  • Clear pass/fail indication for easy use

Seaward PrimeTest 200 suitability

  • PAT testers
  • Service companies
  • Electricians

Seaward PrimeTest 200 comes supplied with

  • Seaward PrimeTest 200 PAT Tester
  • Seaward PrimeTest 200 carry case
  • Seaward PrimeTest 200 user manual
  • Lead set
  • 6 AA batteries
  • 240v Plug to 10amp IEC lead for testing 240v extension cables
  • Instruction manual
  • Soft carry case

Please note this PAT Tester does NOT come with a Calibration Certificate
PATFINDER

Too many to choose from? Use the quick quide:

Show me....

Open
All PAT Testers
Basic PAT Testers
Mid-Range PAT Testers
Professional PAT Testers
What features would you like your PAT tester to have?

 

Battery Powered
Battery Powered
These PAT Testers offer great flexibility as there is no need to plug them into a mains socket.
Manual
Manual
PAT Testers without memory require you to record results in a PAT Log Book. Results can be manually typed into software to create reports.
Extension Lead Test
Extension Lead Test
PAT Testers with an inbuilt lead length calculator for long cables and extension leads will save a lot of headaches.
Downloadable
Downloadable
Generally, PAT Testers with a memory can be downloaded to reporting software. This can then be made into reports.
Earth Bond Test
Earth Bond Test
The Earth Bond Test (Earth Continuity Test) is carried out on all earthed appliances. An Earth Bond Test shows whether the earth conductor is in a satisfactory condition.
Flash Test
Flash Test
Flash Testing is a high tension insulation test which is no longer a requirement in normal PAT Testing. The only time it is required is after the replacement of a major component in an appliance, such as a motor.
Tests IT Equipment
Tests IT Equipment
This PAT Tester is suitable for testing IT and electronic equipment with a low current Earth Bond Test (usually either 100mA or 200mA).
Tester Has Memory
Tester Has Memory
This allows the tester to store an allocated number of tests. These results can then be downloaded into reporting software.
Mains Powered
Mains Powered
These PAT Testers offer a wider range of tests and are powered by a mains socket.
Connects To Printer
Connects To Printer
A Printer can speed up your PAT Testing a great deal. If you require a printer, then you must choose a PAT Tester with printer compatibility.
110v Run Test
110v Run Test
Most industrial and construction equipment is powered by 110v. A 110v Run Test (also known as Load Test) is required for this.
Connects To Scanner
Connects To Scanner
A scanner can speed up your PAT Testing a great deal. If you require a scanner, then you must choose a PAT Tester with scanner compatibility.
Insulation Test
Insulation Test
The Insulation Test measures the insulation resistance of a device under test. A 250v Insulation Test overcomes problems in testing surge protected extension leads.
Calibration Included
Calibration Included
A manufacturer calibration certificate is included with these PAT Testers. This certificate starts from the date of manufacture, so it is recommended that you still add a new calibration certificate.

Features

CATALOGUE

Request a PAT Catalogue full of testers and accessories completely FREE!

PATBRANDS

View all PAT equipment and Accessories by brand

Click the brand you want to see below:

TOPTENS

Want to know what's popular? View our Top Tens.