PAT350 PAT Tester Overview
Manual
PAT Testers without memory require you to record results in a PAT Log Book. Results can be manually typed into software to create reports.
Extension Lead Test
PAT Testers with an inbuilt lead length calculator for long cables and extension leads will save a lot of headaches.

200mA
25A 10A
Earth Bond Test
The Earth Bond Test (Earth Continuity Test) is carried out on all earthed appliances. An Earth Bond Test shows whether the earth conductor is in a satisfactory condition.
Flash Test
Flash Testing is a high tension insulation test which is no longer a requirement in normal PAT Testing. The only time it is required is after the replacement of a major component in an appliance, such as a motor.
Tests IT Equipment
This PAT Tester is suitable for testing IT and electronic equipment with a low current Earth Bond Test (usually either 100mA or 200mA).
Mains Powered
These PAT Testers offer a wider range of tests and are powered by a mains socket.
110v Run Test
Most industrial and construction equipment is powered by 110v. A 110v Run Test (also known as Load Test) is required for this.

250
500V
Insulation Test
The Insulation Test measures the insulation resistance of a device under test. A 250v Insulation Test overcomes problems in testing surge protected extension leads.

5Kg
Weight
If you need to walk between tests make sure you pick a PAT Tester with a comfortable weight.
RCD Test
Many newer PAT testers incorporate this test because it is a requirement of the IEE Code of Practice 3rd Edition.
The new Megger PAT350 PAT Tester is one of two new Portable Appliance Testers from Meggers PAT 300 range.
This portable PAT Tester is ideal for testing all electrical equipment to meet Health and Safety regulations. The Megger PAT350 PAT Tester is a fully featured tester with dedicated test buttons for direct access to tests.
The Megger PAT350 can test a full range of electrical items including Class I, Class II, IEC Power Leads, Extension Leads and full tests for portable RCDs. It also has the ability to carry out Flash Tests. An automatic mode is available for Class I and Class II testing. In automatic mode, the tests proceed sequentially through bond, insulation and operation, indicating a pass or fail at each test.
If a fail occurs, the Megger PAT350 stops testing. When manual testing, each test is preceded by a selection screen where the test parameters are selected, such as bond test current, insulation test voltage or leakage test type. These diagnostic buttons provide direct access to any test individually, allowing single tests to be performed following repair or a suspect result.
Also available in this range is the Megger PAT320. This has all the features of the Megger PAT350 only without the added capability of Flash Test.
Megger PAT350 key features
-
Flash test
-
Simple manual or automatic testing
-
230 V and 110 V operation
-
Bond testing at 25 A,10 A and 200 mA
-
Differential, touch and substitute leakage testing
-
Full colour display
-
Tests portable RCDs and extension leads
Megger PAT350 suitability
-
Bed and breakfasts / hotels
-
Electrical contractors
-
PAT organisations
-
Maintenance and facilities companies
Megger PAT350 comes supplied with
-
Megger PAT350 PAT Tester
-
Megger PAT350 carry case
-
Combined earth-bond and insulation test lead
-
Adaptor for testing extension leads
Further Information:
-
Calibration certificate NOT included
-
Free delivery included
Download Technical PDFs For Further Information On This Product
At PAT Testers we have a comprehensive Help Centre with dozens of answer FAQs and supporting videos. Some related FAQs are below and if you still need some help, why not seach our PAT Tester Help Centre.
Looking for a specific help sheet or video? Then enter you query below and search our comprehensive database for the answer.