Features

Technical Info

Click tab for Datasheets & Manuals

extension
Extension Lead Test
PAT Testers with an inbuilt lead length calculator for long cables and extension leads will save a lot of headaches.
downloadable
Downloadable
Generally, PAT Testers with a memory can be downloaded to reporting software. This can then be made into reports.
earthbond

100mA
25A

Earth Bond Test
The Earth Bond Test (Earth Continuity Test) is carried out on all earthed appliances. An Earth Bond Test shows whether the earth conductor is in a satisfactory condition.
flashtest
Flash Test
Flash Testing is a high tension insulation test which is no longer a requirement in normal PAT Testing. The only time it is required is after the replacement of a major component in an appliance, such as a motor.
it
Tests IT Equipment
This PAT Tester is suitable for testing IT and electronic equipment with a low current Earth Bond Test (usually either 100mA or 200mA).
memory

4000

Tester Has Memory
This allows the tester to store an allocated number of tests. Results can be downloaded into reporting software but can only be viewed on screen if it is a manual PAT tester.
mains
Mains Powered
These PAT Testers offer a wider range of tests and are powered by a mains socket.
printer
Connects To Printer
A Printer can speed up your PAT Testing a great deal. If you require a printer, then you must choose a PAT Tester with printer compatibility.
runtest
110v Run Test
Most industrial and construction equipment is powered by 110v. A 110v Run Test (also known as Load Test) is required for this.
scanner
Connects To Scanner
A scanner can speed up your PAT Testing a great deal. If you require a scanner, then you must choose a PAT Tester with scanner compatibility.
insulation

250
500V

Insulation Test
The Insulation Test measures the insulation resistance of a device under test. A 250v Insulation Test overcomes problems in testing surge protected extension leads.
weight

9.0Kg

Weight
If you need to walk between tests make sure you pick a PAT Tester with a comfortable weight.
calibration
Calibration Included
A manufacturer calibration certificate is included with these PAT Testers. This certificate starts from the date of manufacture, so it is recommended that you still add a new calibration certificate.
rcd
RCD Test
Many newer PAT testers incorporate this test because it is a requirement of the IEE Code of Practice 3rd Edition.

Download technical PDFs for further information on this product.

Get Adobe Acrobat Reader

Description

Metrel’s top of the range PAT Tester is capable of testing portable electrical appliances, IT equipment, IEC cords and portable RCDs with corresponding IEC/EN and VDE standards.

The NEW Metrel OmegaPAT Plus MI 3305 is suitable for periodic testing, troubleshooting or as a tool for electrical safety in workshops. It can be connected to 115 V and 230 V mains supply voltage. Instruments are placed in robust, waterproof case with build in carrying handle.

This PAT Tester has all the functions to speed up your PAT Testing.  The OmegaPAT Plus MI 3305 comes with over 100 pre-programmed auto test sequences, covering most of the test requirements you will come across. You can also define up to 50 additional customised auto tests. Full QWERTY keyboard allows easy data entries.
 

Metrel OmegaPAT Plus MI 3305 supported tests

  • Earth bond continuity test with currents up to 25 A
  • Insulation resistance
  • Leakage current (differentinal, substitute and touch)
  • Functional test
  • Dielectric withstanding test 1500 V and 3000 V AC (Flash test)
  • Polarity test of IEC cord
  • TRMS leakage and load current measurement using clamp current adapter and Trip-out time measurement of portable RCDs


Metrel OmegaPAT Plus MI 3305 key features

  • USB support
  • User-friendly graphic user interface (GUI)
  • Instrument personalisation to user needs
  • Barcode reader and serial printer support
  • Saving auto test results with important information
  • Quickly searching of test results using special filters
  • Downloading/uploading auto test results to/from PC, test results comparison/trends and label printing


Metrel OmegaPAT Plus MI 3305 suitability

  • PAT testers
  • Electrical contractors
  • Facilities managers
  • Schools, colleges and universities
  • High volume testing

 

Metrel OmegaPAT Plus MI 3305 comes supplied with

  • Metrel OmegaPAT Plus MI 3305 PAT Tester
  • Metrel OmegaPAT Plus MI 3305 instruction manual
  • Earth Bond Clip
  • Flash test probe
  • PRCD test probe
  • PC SW PAT Link with RS232 and USB cable
  • Product verification data


This PAT Tester comes with a Calibration Certificate

Help Centre

At PAT Testers we have a comprehensive Help Centre with dozens of answer FAQs and supporting videos. Some related FAQs are below and if you still need some help, why not seach our PAT Tester Help Centre.

PATFINDER

Too many PAT testers to choose from?
Using the quick guide can help:

Show me....

Open
All PAT Testers
Basic
Mid-Range
Professional
What features would you like your PAT tester to have?

 

battery
Battery Powered
These PAT Testers offer great flexibility as there is no need to plug them into a mains socket.
manual
Manual
PAT Testers without memory require you to record results in a PAT Log Book. Results can be manually typed into software to create reports.
extension
Extension Lead Test
PAT Testers with an inbuilt lead length calculator for long cables and extension leads will save a lot of headaches.
downloadable
Downloadable
Generally, PAT Testers with a memory can be downloaded to reporting software. This can then be made into reports.
earthbond
Earth Bond Test
The Earth Bond Test (Earth Continuity Test) is carried out on all earthed appliances. An Earth Bond Test shows whether the earth conductor is in a satisfactory condition.
flashtest
Flash Test
Flash Testing is a high tension insulation test which is no longer a requirement in normal PAT Testing. The only time it is required is after the replacement of a major component in an appliance, such as a motor.
it
Tests IT Equipment
This PAT Tester is suitable for testing IT and electronic equipment with a low current Earth Bond Test (usually either 100mA or 200mA).
memory
Tester Has Memory
This allows the tester to store an allocated number of tests. Results can be downloaded into reporting software but can only be viewed on screen if it is a manual PAT tester.
mains
Mains Powered
These PAT Testers offer a wider range of tests and are powered by a mains socket.
printer
Connects To Printer
A Printer can speed up your PAT Testing a great deal. If you require a printer, then you must choose a PAT Tester with printer compatibility.
runtest
110v Run Test
Most industrial and construction equipment is powered by 110v. A 110v Run Test (also known as Load Test) is required for this.
scanner
Connects To Scanner
A scanner can speed up your PAT Testing a great deal. If you require a scanner, then you must choose a PAT Tester with scanner compatibility.
insulation
Insulation Test
The Insulation Test measures the insulation resistance of a device under test. A 250v Insulation Test overcomes problems in testing surge protected extension leads.
rcd
RCD Test
Many newer PAT testers incorporate this test because it is a requirement of the IEE Code of Practice 3rd Edition.
calibration
Calibration Included
A manufacturer calibration certificate is included with these PAT Testers. This certificate starts from the date of manufacture, so it is recommended that you still add a new calibration certificate.

Features

request a free catalogue
PATBRANDS

View all PAT equipment and Accessories by brand

Click the brand you want to see below: