Metrel OmegaPAT Plus MI 3305 PAT Tester

RRP £1120.00

You Save £261.00

£859.00+VAT  qty

£1009.33 inc VAT

Add Calibration £25.00+VAT

Order Code: MI3305

Features

Extension Lead Test
Extension Lead Test
PAT Testers with an inbuilt lead length calculator for long cables and extension leads will save a lot of headaches.
Downloadable
Downloadable
Generally, PAT Testers with a memory can be downloaded to reporting software. This can then be made into reports.
Earth Bond Test

25A
100mA

Earth Bond Test
The Earth Bond Test (Earth Continuity Test) is carried out on all earthed appliances. An Earth Bond Test shows whether the earth conductor is in a satisfactory condition.
Flash Test
Flash Test
Flash Testing is a high tension insulation test which is no longer a requirement in normal PAT Testing. The only time it is required is after the replacement of a major component in an appliance, such as a motor.
Tests IT Equipment
Tests IT Equipment
This PAT Tester is suitable for testing IT and electronic equipment with a low current Earth Bond Test (usually either 100mA or 200mA).
Tester Has Memory

4000

Tester Has Memory
This allows the tester to store an allocated number of tests. These results can then be downloaded into reporting software.
Mains Powered
Mains Powered
These PAT Testers offer a wider range of tests and are powered by a mains socket.
Connects To Printer
Connects To Printer
A Printer can speed up your PAT Testing a great deal. If you require a printer, then you must choose a PAT Tester with printer compatibility.
110v Run Test
110v Run Test
Most industrial and construction equipment is powered by 110v. A 110v Run Test (also known as Load Test) is required for this.
Connects To Scanner
Connects To Scanner
A scanner can speed up your PAT Testing a great deal. If you require a scanner, then you must choose a PAT Tester with scanner compatibility.
Insulation Test

250
500V

Insulation Test
The Insulation Test measures the insulation resistance of a device under test. A 250v Insulation Test overcomes problems in testing surge protected extension leads.
Weight

9Kg

Weight
If you need to walk between tests make sure you pick a PAT Tester with a comfortable weight.
Calibration Included
Calibration Included
A manufacturer calibration certificate is included with these PAT Testers. This certificate starts from the date of manufacture, so it is recommended that you still add a new calibration certificate.

Description

Metrel’s top of the range PAT Tester is capable of testing portable electrical appliances, IT equipment, IEC cords and portable RCDs with corresponding IEC/EN and VDE standards.

The NEW Metrel OmegaPAT Plus MI 3305 is suitable for periodic testing, troubleshooting or as a tool for electrical safety in workshops. It can be connected to 115 V and 230 V mains supply voltage. Instruments are placed in robust, waterproof case with build in carrying handle.

This PAT Tester has all the functions to speed up your PAT Testing.  The OmegaPAT Plus MI 3305 comes with over 100 pre-programmed auto test sequences, covering most of the test requirements you will come across. You can also define up to 50 additional customised auto tests. Full QWERTY keyboard allows easy data entries.

Metrel OmegaPAT Plus MI 3305 supported tests

  • Earth bond continuity test with currents up to 25 A
  • Insulation resistance
  • Leakage current (differentinal, substitute and touch)
  • Functional test
  • Dielectric withstanding test 1500 V and 3000 V AC (Flash test)
  • Polarity test of IEC cord
  • TRMS leakage and load current measurement using clamp current adapter and Trip-out time measurement of portable RCDs

Metrel OmegaPAT Plus MI 3305 key features

  • USB support
  • User-friendly graphic user interface (GUI)
  • Instrument personalisation to user needs
  • Barcode reader and serial printer support
  • Saving auto test results with important information
  • Quickly searching of test results using special filters
  • Downloading/uploading auto test results to/from PC, test results comparison/trends and label printing

Metrel OmegaPAT Plus MI 3305 suitability

  • PAT testers
  • Electrical contractors
  • Facilities managers
  • Schools, colleges and universities
  • High volume testing

Metrel OmegaPAT Plus MI 3305 comes supplied with

  • Metrel OmegaPAT Plus MI 3305 PAT Tester
  • Metrel OmegaPAT Plus MI 3305 instruction manual
  • Earth Bond Clip
  • Flash test probe
  • PRCD test probe
  • PC SW PAT Link with RS232 and USB cable
  • Product verification data

This PAT Tester comes with a Calibration Certificate
PATFINDER

Too many to choose from? Use the quick quide:

Show me....

Open
All PAT Testers
Basic PAT Testers
Mid-Range PAT Testers
Professional PAT Testers
What features would you like your PAT tester to have?

 

Battery Powered
Battery Powered
These PAT Testers offer great flexibility as there is no need to plug them into a mains socket.
Manual
Manual
PAT Testers without memory require you to record results in a PAT Log Book. Results can be manually typed into software to create reports.
Extension Lead Test
Extension Lead Test
PAT Testers with an inbuilt lead length calculator for long cables and extension leads will save a lot of headaches.
Downloadable
Downloadable
Generally, PAT Testers with a memory can be downloaded to reporting software. This can then be made into reports.
Earth Bond Test
Earth Bond Test
The Earth Bond Test (Earth Continuity Test) is carried out on all earthed appliances. An Earth Bond Test shows whether the earth conductor is in a satisfactory condition.
Flash Test
Flash Test
Flash Testing is a high tension insulation test which is no longer a requirement in normal PAT Testing. The only time it is required is after the replacement of a major component in an appliance, such as a motor.
Tests IT Equipment
Tests IT Equipment
This PAT Tester is suitable for testing IT and electronic equipment with a low current Earth Bond Test (usually either 100mA or 200mA).
Tester Has Memory
Tester Has Memory
This allows the tester to store an allocated number of tests. These results can then be downloaded into reporting software.
Mains Powered
Mains Powered
These PAT Testers offer a wider range of tests and are powered by a mains socket.
Connects To Printer
Connects To Printer
A Printer can speed up your PAT Testing a great deal. If you require a printer, then you must choose a PAT Tester with printer compatibility.
110v Run Test
110v Run Test
Most industrial and construction equipment is powered by 110v. A 110v Run Test (also known as Load Test) is required for this.
Connects To Scanner
Connects To Scanner
A scanner can speed up your PAT Testing a great deal. If you require a scanner, then you must choose a PAT Tester with scanner compatibility.
Insulation Test
Insulation Test
The Insulation Test measures the insulation resistance of a device under test. A 250v Insulation Test overcomes problems in testing surge protected extension leads.
Calibration Included
Calibration Included
A manufacturer calibration certificate is included with these PAT Testers. This certificate starts from the date of manufacture, so it is recommended that you still add a new calibration certificate.

Features

CATALOGUE

Request a PAT Catalogue full of testers and accessories completely FREE!

PATBRANDS

View all PAT equipment and Accessories by brand

Click the brand you want to see below:

TOPTENS

Want to know what's popular? View our Top Tens.