>
PAT320 PAT Tester

Megger PAT320 PAT Tester

Megger PAT320 PAT Tester Kit
Click image above and thumbnails to enlarge.

RRP £795.00

You Save £230.00

£565.00+VAT x  qty

£663.88 inc VAT

Add Calibration £25.00+VAT

Order Code: MEGPT7

Features

Technical Info

Click tab for Datasheets & Manuals

manual
Manual
PAT Testers without memory require you to record results in a PAT Log Book. Results can be manually typed into software to create reports.
extension
Extension Lead Test
PAT Testers with an inbuilt lead length calculator for long cables and extension leads will save a lot of headaches.
earthbond

200mA
25A 10A

Earth Bond Test
The Earth Bond Test (Earth Continuity Test) is carried out on all earthed appliances. An Earth Bond Test shows whether the earth conductor is in a satisfactory condition.
it
Tests IT Equipment
This PAT Tester is suitable for testing IT and electronic equipment with a low current Earth Bond Test (usually either 100mA or 200mA).
mains
Mains Powered
These PAT Testers offer a wider range of tests and are powered by a mains socket.
runtest
110v Run Test
Most industrial and construction equipment is powered by 110v. A 110v Run Test (also known as Load Test) is required for this.
insulation

250
500V

Insulation Test
The Insulation Test measures the insulation resistance of a device under test. A 250v Insulation Test overcomes problems in testing surge protected extension leads.
weight

4.5Kg

Weight
If you need to walk between tests make sure you pick a PAT Tester with a comfortable weight.
rcd
RCD Test
Many newer PAT testers incorporate this test because it is a requirement of the IEE Code of Practice 3rd Edition.

Download technical PDFs for further information on this product.

Get Adobe Acrobat Reader

Description

The PAT320 from Megger is an all new PAT tester to the market. This latest Megger PAT is part of the 300 series of testers.

This tester was designed to simplify PAT testing. The design means that you select which test that you want to complete by pushing the dedicated test button. 

The Megger PAT320 can do a range of tests on portable appliances including the Class 1, Class 2, Extension leads, IEC power leads, used on a lot of IT equipment, it also carries out RCD tests.  The tester has an automatic test mode for carrying out the Class 1 and Class II testing.

The “auto” mode tests sequentially through bond, insulation and operation, displaying a pass or fail result for each test.

This tester is great for electricians who occasionally carry out some PAT testing and don’t need a downloadable tester that stores test results.

When a fail is detected the tester will stop testing. You can set the parameters of testing for each test such as the bond current, insulation and leakage. You can also carry out individual tests, for example, following a repair, or if you have had a suspect reading.

The other tester available in this range is the Megger PAT350 - this is a similar model with added flash test capability.

 

Key features of the Megger PAT320 PAT Tester

  • Simple manual or automatic testing
  • 230v and 110v operation
  • Bond testing at 25A,10A and 200mA
  • Differential, touch and substitute leakage testing
  • Full colour display
  • Tests portable RCDs and extension leads

 

Megger PAT320 PAT Tester suitability

  • Bed and breakfasts / hotels
  • PAT organisations
  • Electrical contractors
  • Maintenance and facilities companies

 

Megger PAT320 PAT Tester comes supplied with

  • Megger PAT320 PAT Tester
  • Combined earth-bond and insulation test lead
  • Megger PAT320 carry case
  • Adaptor for testing extension leads

Further information:

  • Calibration certificate not included
  • Free delivery included

Help Centre

At PAT Testers we have a comprehensive Help Centre with dozens of answer FAQs and supporting videos. Some related FAQs are below and if you still need some help, why not seach our PAT Tester Help Centre.

PATFINDER

Too many PAT testers to choose from?
Using the quick guide can help:

Show me....

Open
All PAT Testers
Basic
Mid-Range
Professional
What features would you like your PAT tester to have?

 

battery
Battery Powered
These PAT Testers offer great flexibility as there is no need to plug them into a mains socket.
manual
Manual
PAT Testers without memory require you to record results in a PAT Log Book. Results can be manually typed into software to create reports.
extension
Extension Lead Test
PAT Testers with an inbuilt lead length calculator for long cables and extension leads will save a lot of headaches.
downloadable
Downloadable
Generally, PAT Testers with a memory can be downloaded to reporting software. This can then be made into reports.
earthbond
Earth Bond Test
The Earth Bond Test (Earth Continuity Test) is carried out on all earthed appliances. An Earth Bond Test shows whether the earth conductor is in a satisfactory condition.
flashtest
Flash Test
Flash Testing is a high tension insulation test which is no longer a requirement in normal PAT Testing. The only time it is required is after the replacement of a major component in an appliance, such as a motor.
it
Tests IT Equipment
This PAT Tester is suitable for testing IT and electronic equipment with a low current Earth Bond Test (usually either 100mA or 200mA).
memory
Tester Has Memory
This allows the tester to store an allocated number of tests. Results can be downloaded into reporting software but can only be viewed on screen if it is a manual PAT tester.
mains
Mains Powered
These PAT Testers offer a wider range of tests and are powered by a mains socket.
printer
Connects To Printer
A Printer can speed up your PAT Testing a great deal. If you require a printer, then you must choose a PAT Tester with printer compatibility.
runtest
110v Run Test
Most industrial and construction equipment is powered by 110v. A 110v Run Test (also known as Load Test) is required for this.
scanner
Connects To Scanner
A scanner can speed up your PAT Testing a great deal. If you require a scanner, then you must choose a PAT Tester with scanner compatibility.
insulation
Insulation Test
The Insulation Test measures the insulation resistance of a device under test. A 250v Insulation Test overcomes problems in testing surge protected extension leads.
rcd
RCD Test
Many newer PAT testers incorporate this test because it is a requirement of the IEE Code of Practice 3rd Edition.
calibration
Calibration Included
A manufacturer calibration certificate is included with these PAT Testers. This certificate starts from the date of manufacture, so it is recommended that you still add a new calibration certificate.

Features

request a free catalogue
PATBRANDS

View all PAT equipment and Accessories by brand

Click the brand you want to see below: