Kewtech KT71 PAT Tester

RRP £575.00

You Save £260.00

£315.00+VAT  qty

£370.13 inc VAT

Add Calibration £25.00+VAT

Order Code: KEWPT3

Features

Manual
Manual
PAT Testers without memory require you to record results in a PAT Log Book. Results can be manually typed into software to create reports.
Extension Lead Test
Extension Lead Test
PAT Testers with an inbuilt lead length calculator for long cables and extension leads will save a lot of headaches.
Earth Bond Test

200mA
20A

Earth Bond Test
The Earth Bond Test (Earth Continuity Test) is carried out on all earthed appliances. An Earth Bond Test shows whether the earth conductor is in a satisfactory condition.
Tests IT Equipment
Tests IT Equipment
This PAT Tester is suitable for testing IT and electronic equipment with a low current Earth Bond Test (usually either 100mA or 200mA).
Mains Powered
Mains Powered
These PAT Testers offer a wider range of tests and are powered by a mains socket.
Insulation Test

250
500V

Insulation Test
The Insulation Test measures the insulation resistance of a device under test. A 250v Insulation Test overcomes problems in testing surge protected extension leads.
Weight

1.2Kg

Weight
If you need to walk between tests make sure you pick a PAT Tester with a comfortable weight.
Calibration Included
Calibration Included
A manufacturer calibration certificate is included with these PAT Testers. This certificate starts from the date of manufacture, so it is recommended that you still add a new calibration certificate.

Description

The Kewtech KT71 PAT Tester is a popular mains powered PAT Pester. It is Easy to use and great for low volume testing!

The Kewtech KT71 is great for in-house maintenance staff who conduct their own yearly PAT Testing. It is also suitable for electrical contractors who need to have a PAT Testing capability, but for whom it is not core for their business. Anyone can easily be trained to use this instrument with complete safety.

LED indicators give visual pass/fail indication with limits set in accordance with the IET (IEE) Code of Practice. This means that, in most cases, users will not have to interpret the results. However if you wish the Kewtech KT71 PAT Tester gives you the readings on the LCD screen.

When switching to live testing (in leakage current mode) audible warnings are given that the appliance is about to come live. A double button press is also required to safeguard against inadvertent switching on of an appliance.
 

PAT Testing with the Kewtech KT71

Class I Test
the Kewtech KT71 automatically goes through the test sequence, for example, it performs the sequence of an earth bond test at 200mA, followed by a check to see whether the user has not forgotten to switch the instrument on, then an insultation test.

The insultation test has a 250V or 500V option and the test sequence also has an option whether a leakage current test is done instead of an insultation test. This corresponds to the IEE Code of Practice which supports a leakage test where insultation tests cannot be safely conducted.

Class I 20A test
Performs the sequence of an earth bond test at 20A, followed by a check to see whether the user has not forgotten to switch the instrument on, then an insulation test.

The Kewtech KT71 insulation test has a 250V or 500V option and the test sequence has an alternative of a leakage current test instead of the insulation test.

This corresponds to the IEE Code of Practice which supports a leakage test where insulation tests cannot be safely conducted or are suspect.

Class II Test
The Class II sequence tests whether the appliance is switched on and then runs an insulation test. A leakage current test (touch current test) can be conducted as an alternative.

Leakage Current (Touch Current) Test
The Leakage Current Test is conducted at mains voltage, a load test and a leakage test is undertaken and the results are shown alternatively on the Kewtech KT71's screen. (Testing at mains voltage gives superior results than instruments that perform this by subsequent leakage tests).
 

Kewtech KT71 key features

  • Easy to use
  • Screen gives PASS/FAIL and test readings
  • Hand held - Portable size
  • Mains powered

 

Kewtech KT71 suitability

  • Maintenance staff
  • Schools and colleges
  • Low volume users
  • Leisure industry
  • Care homes

 

Kewtech KT71 comes supplied with

  • Kewtech KT71 PAT Tester
  • Kewtech KT71 user manual
  • Earth bond test lead
  • 6 rechargeable batteries
  • Mains lead and car charger
  • 2 year warranty

This PAT Tester comes with a Calibration Certificate

PATFINDER

Too many to choose from? Use the quick quide:

Show me....

Open
All PAT Testers
Basic PAT Testers
Mid-Range PAT Testers
Professional PAT Testers
What features would you like your PAT tester to have?

 

Battery Powered
Battery Powered
These PAT Testers offer great flexibility as there is no need to plug them into a mains socket.
Manual
Manual
PAT Testers without memory require you to record results in a PAT Log Book. Results can be manually typed into software to create reports.
Extension Lead Test
Extension Lead Test
PAT Testers with an inbuilt lead length calculator for long cables and extension leads will save a lot of headaches.
Downloadable
Downloadable
Generally, PAT Testers with a memory can be downloaded to reporting software. This can then be made into reports.
Earth Bond Test
Earth Bond Test
The Earth Bond Test (Earth Continuity Test) is carried out on all earthed appliances. An Earth Bond Test shows whether the earth conductor is in a satisfactory condition.
Flash Test
Flash Test
Flash Testing is a high tension insulation test which is no longer a requirement in normal PAT Testing. The only time it is required is after the replacement of a major component in an appliance, such as a motor.
Tests IT Equipment
Tests IT Equipment
This PAT Tester is suitable for testing IT and electronic equipment with a low current Earth Bond Test (usually either 100mA or 200mA).
Tester Has Memory
Tester Has Memory
This allows the tester to store an allocated number of tests. These results can then be downloaded into reporting software.
Mains Powered
Mains Powered
These PAT Testers offer a wider range of tests and are powered by a mains socket.
Connects To Printer
Connects To Printer
A Printer can speed up your PAT Testing a great deal. If you require a printer, then you must choose a PAT Tester with printer compatibility.
110v Run Test
110v Run Test
Most industrial and construction equipment is powered by 110v. A 110v Run Test (also known as Load Test) is required for this.
Connects To Scanner
Connects To Scanner
A scanner can speed up your PAT Testing a great deal. If you require a scanner, then you must choose a PAT Tester with scanner compatibility.
Insulation Test
Insulation Test
The Insulation Test measures the insulation resistance of a device under test. A 250v Insulation Test overcomes problems in testing surge protected extension leads.
Calibration Included
Calibration Included
A manufacturer calibration certificate is included with these PAT Testers. This certificate starts from the date of manufacture, so it is recommended that you still add a new calibration certificate.

Features

CATALOGUE

Request a PAT Catalogue full of testers and accessories completely FREE!

PATBRANDS

View all PAT equipment and Accessories by brand

Click the brand you want to see below:

TOPTENS

Want to know what's popular? View our Top Tens.